Cold water meter multi-jet DN50, pulse output, Dimm (meters) -ref. DHM1000-50300
Part number ART072136 · Water meters
Net prices excl. VAT and ordering are reserved for signed-in professional accounts.
Cold water meter multi-jet DN50, pulse output, Dimm (meters), water metering with pulse output, distributed by DIMM.
Why meter water
Metering water means controlling it: metering and sub-metering allow you to track consumption by point of use, fairly distribute charges between occupants or workshops, detect leaks by comparing readings and bill based on actual consumption. A reliable meter with pulse output integrates into building management systems (BMS) or remote reading systems for automated monitoring without on-site visits.
Principle
This multi-jet water meter measures potable or slightly contaminated water consumption with excellent accuracy, even at low flow rates. With pulse output, it covers a wide range of diameters (DN15 to DN50) for domestic and industrial applications.
Operation
The multi-jet principle distributes water onto the turbine through multiple orifices, improving accuracy and longevity compared to single-jet designs. Dry dial, magnetic transmission anti-fraud, R=80 ratio in horizontal position, externally adjustable sealed screw. Pulse output (12 values) feeds remote reading and sub-metering.
Applications
Applications: Sub-metering, Remote reading / BMS, Industry, Water networks.
Specifications
| Brand | Dimm |
| Reference | DHM1000-50300 |
| Diameter | DN50 |
| Water type | Cold |
| Connection | Hose 2'' |
| Output | Pulse |
Key features
- Pulse output (remote reading / BMS / sub-metering)
- Dry dial with magnetic transmission (anti-fraud)
- Brass body epoxy-coated, hermetically sealed totaliser
- 12 pulse values, up to 2 outputs
- Stable materials for reliable reading over time
Reliability & anti-fraud
A water meter's reliability depends on its design: dry dial isolated from water, magnetic transmission between turbine and totaliser (which also protects against magnet fraud), hermetically sealed totaliser to remain readable over time, and brass body epoxy-coated or cast iron resistant to corrosion. These choices guarantee stable measurement and high longevity, even with slightly contaminated water.
Remote reading & control
Combined with pulse output, remote reading transforms metering into a management tool: readings are automatically sent to a building management system or software, without manual collection. You visualise consumption by point of use, distribute charges, spot overconsumption or leaks as soon as abnormal flow persists at night, and trigger alerts. This is the foundation of a water-saving and cost-control strategy.
DIMM metering range
This reference is part of the DIMM water metering range: single-jet, multi-jet, Woltmann and combination meters, pulse transmitters, protection filters, isolation valves and accessories combine to equip a complete metering point, from small domestic sub-meters to large industrial meters with remote reading.
Water saving & sustainability
Better measurement means better consumption: accurate metering and reliable remote reading reveal waste, encourage more responsible behaviour and quickly pay for the installation. Durable materials and a protected mechanism limit replacements, for a solution that is both economical and respectful of water resources.
Choosing the right meter
Meter selection is based on the flow rate to be measured and the pipe diameter (DN), temperature (cold or hot water), and measurement range (ratio R). Single-jet meters suit small domestic diameters, multi-jet offers better accuracy at low flow, Woltmann handles high flows with low pressure drop, and combination meters cover a very wide range. DIMM helps you size according to your installation.
Pulse output
Pulse output converts a volume of water into electrical signals: each pulse corresponds to a predefined volume (pulse value, adjustable among several values). Connected to a data logger, controller or BMS, it enables remote reading, leak alarm, distribution and proportional flow control. Depending on the model, two outputs (identical or different) and flow direction are available.
Installation & maintenance
Installation is on a full pipe, in the direction of the arrow, preferably horizontal to preserve accuracy (maximum ratio). Respect recommended upstream/downstream straight lengths and install a filter upstream to protect the mechanism. Isolation valves facilitate removal. Maintenance is minimal: periodic inspection and replacement at end of metrological life.
Distributed by DIMM, specialist in water treatment and metering in Belgium and France, this product benefits from expert technical advice, available parts and accessories, and long-term support.
Water meters
- 2 BRASS FITTINGS FOR DN 50 METERS - NUT THREAD 2 1/2" (66/76) SOCKET THREAD R 2" (50/60) - ref. DHRAC-50 ref. ART072137
- water meter Woltmann, pulse output, Dimm (meters) ref. ART072138
- Cold water Woltmann meter DN80, pulse output, Dimm (meters) ref. ART072120
- 2 BRASS FITTINGS FOR METERS DN 25 - NUT THREAD 1"1/4 (33/42) SOCKET THREAD R 1" (26/34) - ref. DHRAC-25 ref. ART071812
- MULTI-JET COLD WATER METER - RATIO R80 DN40 - 1''1/2 HOSE - 2'' METER PULSE CABLE AND FITTINGS OPTIONAL INDICATE PULSE VALUES - ref. DHM1000-40300 ref. ART072655
- Cold water meter Woltmann DN50, pulse output, Dimm (meters) ref. ART072672
- Cold water meter multi-jet DN20, pulse output, Dimm (meters) ref. ART072766
- Flanged strainer for water meter, DN25, Dimm (meters) ref. ART072767
- Cold water meter multi-jet DN25, pulse output, Dimm (meters) ref. ART072769
- CABLE FOR METER - REED TYPE FOR DHW1xxx METERS RANGE 3 DUAL REED CONTACT CABLES (2 OUTPUTS) - ref. DHWREED-DUAL ref. ART072770
- Pulse emitter for water meter, Dimm (meters) ref. ART071174
- Cold water meter Woltmann DN652, pulse output, Dimm (meters) ref. ART074012
- Hot water meter multi-jet DN302, pulse output, Dimm (meters) ref. ART074041
- Cold water meter Woltmann DN100, pulse output, Dimm (meters) ref. ART078855
- Hot water meter multi-jet DN151, pulse output, Dimm (meters) ref. ART057343
- Cold water meter multi-jet DN15, pulse output, Dimm (meters) ref. ART057342
- Flanged strainer for water meter, DN20, Dimm (meters) ref. ART081791
- Cold water meter single-jet DN20, pulse output, Dimm (meters) ref. ART088327
- Cold water meter combined Woltmann DN50, pulse output, Dimm (meters) ref. ART088446
- Cold water meter Woltmann DN125, pulse output, Dimm (meters) ref. ART089507
- Cold water meter combined Woltmann DN100, pulse output, Dimm (meters) ref. ART089508
- Cold water meter single-jet DN201, pulse output, Dimm (meters) ref. ART090178
- Cold water meter Woltmann DN150, pulse output, Dimm (meters) ref. ART090181
- Cold water meter Woltmann DN200, pulse output, Dimm (meters) ref. ART090182
- Cold water meter Woltmann DN250, pulse output, Dimm (meters) ref. ART090183
- Cold water meter Woltmann DN300, pulse output, Dimm (meters) ref. ART090184
- Cold water meter Woltmann DN400, pulse output, Dimm (meters) ref. ART090185
- Cold water meter Woltmann DN500, pulse output, Dimm (meters) ref. ART090186
- Cold water meter combined Woltmann DN65, pulse output, Dimm (meters) ref. ART090187
- Cold water meter combined Woltmann DN80, pulse output, Dimm (meters) ref. ART090188