Why meter water
Metering water means controlling it: metering and sub-metering track consumption point by point, fairly allocate costs between occupants or workshops, detect leaks by comparing indexes and bill on actual use. A reliable meter with a pulse output integrates into a supervision system (BMS) or remote-reading setup for automated monitoring with no site visit.
Principle
This single-jet water meter measures potable or lightly loaded water consumption, with a pulse output for remote reading, BMS or sub-metering. Compact and reliable, it suits domestic and industrial applications in small diameters (DN15-DN20).
How it works
Single-jet metering directs water onto a turbine; the dry dial with magnetic drive protects the mechanism and prevents magnetic fraud. The ratio reaches R=80 horizontally. The pulse output (adjustable among 12 values, up to 2 identical or different pulses) integrates metering into a remote-reading system.
Applications
Applications: Sous-comptage, Relève à distance / GTB, Industrie, Réseaux d'eau.
Specifications
| Brand | Dimm |
| Reference | DHS1000-20130 |
| Diameter | DN201 |
| Water type | Cold |
| Output | Pulse |
Key strengths
- Pulse output (remote reading / BMS / sub-metering)
- Dry dial, magnetic drive (anti-fraud)
- Epoxy-coated brass body, hermetic register
- 12 pulse values, up to 2 outputs
- Stable materials for reliable long-term reading
Reliability & anti-fraud
A water meter's reliability lies in its design: dry dial isolated from the water, magnetic transmission between turbine and register (which also protects against magnet fraud), a hermetically sealed register to stay readable over time, and an epoxy-coated brass or corrosion-resistant cast-iron body. These choices ensure stable measurement and long life, even on lightly loaded water.
Remote reading & control
Paired with the pulse output, remote reading turns metering into a management tool: indexes are sent automatically to a supervision system or software, with no manual reading. You visualise consumption by point, allocate costs, spot overuse or a leak as soon as an abnormal flow persists at night, and trigger alerts. It is the basis for water saving and cost control.
DIMM metering range
This reference is part of DIMM's water-metering range: single-jet, multi-jet, Woltmann and combined meters, pulse emitters, protective strainers, isolation valves and accessories combine to build a complete metering point, from small domestic sub-meters to large remotely-read industrial meters.
Water saving & durability
Measuring better means consuming better: accurate metering and reliable remote reading reveal waste, encourage more frugal behaviour and quickly pay back the installation. Durable materials and a protected mechanism limit replacements, for a solution that is both economical and respectful of the water resource.
Choosing the right meter
Choosing a meter depends on the flow to measure and pipe diameter (DN), temperature (cold or hot water) and measuring range (ratio R). Single-jet meters suit small domestic diameters, multi-jet offer better low-flow accuracy, Woltmann handle high flows with low pressure drop, and combined meters cover a very wide range. DIMM helps size to your installation.
The pulse output
The pulse output turns a water volume into electrical signals: each pulse corresponds to a preset volume (pulse value, adjustable among several values). Connected to a logger, PLC or BMS, it enables remote reading, leak alarms, allocation and volume-proportional control. Depending on the model, two outputs (identical or different) and flow direction are available.
Installation & maintenance
Installation is on a full pipe, in the arrow direction, preferably horizontal to preserve accuracy (maximum ratio). Follow the recommended upstream/downstream straight lengths and fit a strainer upstream to protect the mechanism. Isolation valves ease removal. Maintenance is minimal: periodic checks and replacement at metrological end of life.
Distributed by DIMM, a specialist in water treatment and metering in Belgium and France, this item benefits from expert technical advice, available parts and accessories and long-term support.
Water meters
- Cold water meter Woltmann DN150, pulse output, Dimm (meters) ref. ART090181
- Cold water meter Woltmann DN200, pulse output, Dimm (meters) ref. ART090182
- Cold water meter Woltmann DN250, pulse output, Dimm (meters) ref. ART090183
- Cold water meter Woltmann DN300, pulse output, Dimm (meters) ref. ART090184
- Cold water meter Woltmann DN400, pulse output, Dimm (meters) ref. ART090185
- Cold water meter Woltmann DN500, pulse output, Dimm (meters) ref. ART090186
- Cold water meter combined Woltmann DN65, pulse output, Dimm (meters) ref. ART090187
- Cold water meter combined Woltmann DN80, pulse output, Dimm (meters) ref. ART090188
- Hot water meter single-jet DN151, pulse output, Dimm (meters) ref. ART090198
- Hot water meter single-jet DN201, pulse output, Dimm (meters) ref. ART090199
- Hot water meter multi-jet DN201, pulse output, Dimm (meters) ref. ART090200
- Hot water meter multi-jet DN252, pulse output, Dimm (meters) ref. ART090201
- Hot water meter multi-jet DN403, pulse output, Dimm (meters) ref. ART090202
- Hot water meter multi-jet DN503, pulse output, Dimm (meters) ref. ART090203
- Hot water meter Woltmann DN50, pulse output, Dimm (meters) ref. ART090206
- Hot water meter Woltmann DN65, pulse output, Dimm (meters) ref. ART090207
- Hot water meter Woltmann DN80, pulse output, Dimm (meters) ref. ART090208
- Hot water meter Woltmann DN100, pulse output, Dimm (meters) ref. ART090209
- Hot water meter Woltmann DN125, pulse output, Dimm (meters) ref. ART090210
- Hot water meter Woltmann DN150, pulse output, Dimm (meters) ref. ART090211
- Hot water meter Woltmann DN200, pulse output, Dimm (meters) ref. ART090212
- Hot water meter Woltmann DN250, pulse output, Dimm (meters) ref. ART090213
- Hot water meter Woltmann DN300, pulse output, Dimm (meters) ref. ART090214
- Hot water meter Woltmann DN400, pulse output, Dimm (meters) ref. ART090215
- Hot water meter Woltmann DN500, pulse output, Dimm (meters) ref. ART090216
- Hot water meter combined Woltmann DN50, pulse output, Dimm (meters) ref. ART090217
- Hot water meter combined Woltmann DN652, pulse output, Dimm (meters) ref. ART090218
- Hot water meter combined Woltmann DN80, pulse output, Dimm (meters) ref. ART090219
- Hot water meter combined Woltmann DN100, pulse output, Dimm (meters) ref. ART090220
- water meter multi-jet DN20, pulse output, Dimm (meters) ref. ART090221